В наличии
AL4RPV-50R
Features and Benefits
- This product is part of the CommScope Wired for Wireless® Solution
Характеристики
Operating Frequency Band
|
1 – 6000 MHz |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-20 °C to +85 °C (-4 °F to +185 °F) |
Product Type
|
Air coaxial cable |
Характеристики
Operating Frequency Band
|
1 – 6000 MHz |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-20 °C to +85 °C (-4 °F to +185 °F) |
Product Type
|
Air coaxial cable |
Diameter Over Jacket
|
15.748 mm | 0.62 in |
Jacket Material
|
PVC |
Product Brand
|
HELIAX® |
Ordering Note
|
CommScope® standard product (Global) |
Installation temperature
|
-5 °C to +60 °C (+23 °F to +140 °F) |
Storage Temperature
|
-20 °C to +85 °C (-4 °F to +185 °F) |
Attenuation, Ambient Temperature
|
20 °C | 68 °F |
Average Power, Ambient Temperature
|
40 °C | 104 °F |
Cable weight
|
0.208 kg/m | 0.14 lb/ft |
Jacket Color
|
Red |
Fire Retardancy Test Method
|
NFPA 262/CATVP/CMP |
Peak Power
|
40 kW |
Product Series
|
AL4-50 |
Capacitance
|
75.459 pF/m | 23 pF/ft |
806–960 MHz
|
1.130 |
dc Test Voltage
|
4000 V |
Cable Impedance
|
50 ohm ±2 ohm |
Average Power, Inner Conductor Temperature
|
100 °C | 212 °F |
Nominal Size
|
1/2 in |
1700–2200 MHz
|
1.130 |
Minimum Bend Radius, multiple Bends
|
127 mm | 5 in |
Minimum Bend Radius, Single Bend
|
63.5 mm | 2.5 in |
Dielectric Material
|
PE spline |
Velocity
|
88 % |
1.0 MHz
|
0.216 |
10.0 MHz
|
0.691 |
100.0 MHz
|
2.274 |
1000.0 MHz
|
8.081 |
50.0 MHz
|
1.581 |
108.0 MHz
|
2.368 |
200.0 MHz
|
3.292 |
400.0 MHz
|
4.808 |
700.0 MHz
|
6.583 |
1800.0 MHz
|
11.439 |
2000.0 MHz
|
12.192 |
2300.0 MHz
|
13.276 |
2500.0 MHz
|
13.975 |
500.0 MHz
|
5.445 |
2700.0 MHz
|
14.656 |
3000.0 MHz
|
15.649 |
85.0 MHz
|
2.087 |
204.0 MHz
|
3.327 |
300.0 MHz
|
4.104 |
450.0 MHz
|
5.134 |
600.0 MHz
|
6.032 |
1218.0 MHz
|
9.068 |
1500.0 MHz
|
10.256 |
1700.0 MHz
|
11.053 |
1794.0 MHz
|
11.416 |
2200.0 MHz
|
12.920 |
1250.0 MHz
|
9.207 |
Outer Conductor Material
|
Corrugated aluminum |
Flexibility
|
Standard |
Inner Conductor OD
|
4.572 mm | 0.18 in |
Outer Conductor OD
|
14.046 mm | 0.553 in |
dc Resistance, Inner Conductor
|
1.575 ohms/km | 0.48 ohms/kft |
dc Resistance, Outer Conductor
|
1.575 ohms/km | 0.48 ohms/kft |
Inductance
|
0.19 µH/m | 0.058 µH/ft |
Insulation Resistance
|
100000 MOhms-km |
Jacket Spark Test Voltage (rms)
|
5000 V |
Power Attenuation
|
2.325000047683716 |
Pulse Reflection
|
0.5% |
1.5 MHz
|
0.264 |
2.0 MHz
|
0.306 |
20.0 MHz
|
0.985 |
30.0 MHz
|
1.213 |
88.0 MHz
|
2.126 |
150.0 MHz
|
2.821 |
174.0 MHz
|
3.054 |
460.0 MHz
|
5.197 |
512.0 MHz
|
5.517 |
800.0 MHz
|
7.105 |
824.0 MHz
|
7.227 |
894.0 MHz
|
7.574 |
960.0 MHz
|
7.892 |
2100.0 MHz
|
12.559 |
3400.0 MHz
|
16.928 |
3600.0 MHz
|
17.551 |
3700.0 MHz
|
17.859 |
3800.0 MHz
|
18.164 |
3900.0 MHz
|
18.467 |
4000.0 MHz
|
18.768 |
4100.0 MHz
|
19.066 |
4200.0 MHz
|
19.363 |
4300.0 MHz
|
19.658 |
4400.0 MHz
|
19.951 |
4500.0 MHz
|
20.241 |
4600.0 MHz
|
20.531 |
4700.0 MHz
|
20.818 |
4800.0 MHz
|
21.104 |
4900.0 MHz
|
21.388 |
5000.0 MHz
|
21.671 |
6000.0 MHz
|
24.420 |
700–894 MHz
|
1.130 |
Inner Conductor Material
|
Copper-clad aluminum wire |
Number of Bends, minimum
|
15 |
Tensile Strength
|
79 kg | 174.165 lb |
Bending Moment
|
6.779 N-m | 5 ft lb |
Flat Plate Crush Strength
|
1.429 kg/mm | 80 lb/in |
c(ETL)us Certification
|
CATVP/CMP |
ETL Certification
|