В наличии
760251722 | P-004-DZ-5K-FSUAQ
Характеристики
Operating Temperature
|
-20 °C to +70 °C (-4 °F to +158 °F) |
Product Type
|
Fiber indoor cable |
Diameter Over Jacket
|
12.8 mm | 0.504 in |
Regional Availability
|
Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America |
Характеристики
Operating Temperature
|
-20 °C to +70 °C (-4 °F to +158 °F) |
Product Type
|
Fiber indoor cable |
Diameter Over Jacket
|
12.8 mm | 0.504 in |
Regional Availability
|
Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America |
Installation temperature
|
0 °C to +70 °C (+32 °F to +158 °F) |
Storage Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Cable weight
|
138 kg/km | 92.732 lb/kft |
Jacket Color
|
Aqua |
Product Series
|
P-DZ |
Cable Type
|
Distribution |
Environmental Space
|
Plenum |
Fiber Type
|
OM4, LazrSPEED® 550 |
Portfolio
|
CommScope® |
Construction Type
|
Armored |
Minimum Bend Radius, loaded
|
192 mm | 7.559 in |
Minimum Bend Radius, unloaded
|
128 mm | 5.039 in |
Tensile Load, long term, maximum
|
200 N | 44.962 lbf |
Tensile Load, short term, maximum
|
667 N | 149.948 lbf |
Flame Test Method
|
NFPA 130 | NFPA 262 |
Jacket Marking
|
Feet |
Flame Test Listing
|
NEC OFCP (ETL) and c(ETL) |
Total Fiber Count
|
4 |
Fiber Type, quantity
|
4 |
Subunit Type
|
Gel-free |
Compression
|
85 N/mm | 485.363 lb/in |
Compression Test Method
|
FOTP-41 | IEC 60794-1 E3 |
Flex
|
25 cycles |
Flex Test Method
|
FOTP-104 | IEC 60794-1 E6 |
Impact
|
35 N-m | 309.776 in lb |
Impact Test Method
|
FOTP-25 | IEC 60794-1 E4 |
Strain
|
See long and short term tensile loads |
Strain Test Method
|
FOTP-33 | IEC 60794-1 E1 |
Twist
|
10 cycles |
Twist Test Method
|
FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum
|
148 m | 485.564 ft |
Cable Qualification Standards
|
ANSI/ICEA S-83-596 | Telcordia GR-409 |
Heat Age Test Method
|
IEC 60794-1 F9 |
Low High Bend
|
-20 °C to +70 °C (-4 °F to +158 °F) |
Low High Bend Test Method
|
FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle
|
-20 °C to +70 °C (-4 °F to +158 °F) |
Temperature Cycle Test Method
|
FOTP-3 | IEC 60794-1 F1 |
Heat Age
|
-20 °C to +85 °C (-4 °F to +185 °F) |
Armor Type
|
Interlocking aluminum |
Diameter Over Armor
|
10.8 mm | 0.425 in |
Поддержка продукта
- product?brand=commscope
- 56582-interlocking-armor-foc-installation-guide-2-1-19-pdf.pdf
- productcompliance?pn=760251722
- 912556-p360-760251722-external.pdf
- 912555-p360-760251722-comprehensiveexternal.pdf
- 57712-network-infrastructure-system-extended-warranty-br-111043-en-06-06-2018-pdf.pdf
- 56950-limited-product-warranty-co-110464-en-11-01-2016-pdf.pdf