В наличии
810009919/DB | C-004-DN-8G-M04WH/15G/V6/D
Характеристики
Operating Temperature
|
-25 °C to +70 °C (-13 °F to +158 °F) |
Product Type
|
Fiber drop cable |
Diameter Over Jacket
|
4.5 mm | 0.177 in |
Jacket Material
|
High density polyethylene (HDPE) | Low Smoke Zero Halogen (LSZH) |
Характеристики
Operating Temperature
|
-25 °C to +70 °C (-13 °F to +158 °F) |
Product Type
|
Fiber drop cable |
Diameter Over Jacket
|
4.5 mm | 0.177 in |
Jacket Material
|
High density polyethylene (HDPE) | Low Smoke Zero Halogen (LSZH) |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | North America |
Installation temperature
|
-0 °C to +60 °C (-32 °F to +140 °F) |
Storage Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Cable weight
|
26 kg/km | 17.471 lb/kft |
Jacket Color
|
White |
Product Series
|
C-DN |
Cable Type
|
Central loose tube | Drop | Tight buffer |
Environmental Space
|
Drop | Ducted | Façade | Indoor/Outdoor | UV resistant for outdoor and Low Smoke Zero Halogen |
Fiber Type
|
G.657.A2 |
Portfolio
|
CommScope® |
Cable Length
|
1999.793 m | 6561 m |
EN50575 CPR Cable EuroClass Fire Performance
|
Dca |
Construction Type
|
Breakout | Non-armored |
Fibers per Subunit, quantity
|
4 |
Jacket UV Resistance
|
UV stabilized |
Minimum Bend Radius, loaded
|
75 mm | 2.953 in |
Tensile Load, long term, maximum
|
300 N | 67.443 lbf |
Tensile Load, short term, maximum
|
1000 N | 224.809 lbf |
EN50575 CPR Cable EuroClass Smoke Rating
|
s1 |
EN50575 CPR Cable EuroClass Droplets Rating
|
d0 |
EN50575 CPR Cable EuroClass Acidity Rating
|
a1 |
Jacket Marking
|
Meters |
Total Fiber Count
|
4 |
Subunit Type
|
Gel-filled |
Subunit, quantity
|
1 |
Buffer Tube/Subunit Diameter
|
1.5 mm | 0.059 in |
Compression
|
10 N/mm | 57.101 lb/in |
Compression Test Method
|
IEC 60794-1 E3 |
Impact
|
2 N-m | 17.701 in lb |
Impact Test Method
|
IEC 60794-1 E4 |
Strain
|
See long and short term tensile loads |
Strain Test Method
|
IEC 60794-1 E1 |
Twist
|
5 cycles |
Twist Test Method
|
IEC 60794-1 E7 |
Cable Qualification Standards
|
IEC 60794-1-2 |
Water Penentration
|
24 h |
Water Penentration Test Method
|
IEC 60794-1 F5 |
Temperature Cycle
|
-25 °C to +70 °C (-13 °F to +158 °F) |
Temperature Cycle Test Method
|
IEC 60794-1-22 F1 |
Inner Jacket Color
|
White |