В наличии
4101204/10 | 2287V WTRL RG11 QD 1000
Характеристики
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Характеристики
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Product Type
|
Coaxial video cable |
Jacket Material
|
PVC |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Packaging Type
|
Reel |
Cable weight
|
102.683 kg/km | 69 lb/kft |
Jacket Color
|
White |
Cable Type
|
Series 11 |
Environmental Space
|
Plenum |
Portfolio
|
CommScope® |
Safety Standard
|
ETL | cETL |
Capacitance
|
52.493 pF/m | 16 pF/ft |
Cable Length
|
304.8 m | 1000 ft |
Construction Type
|
Non-armored |
Product Number
|
2287V |
Nominal Velocity of Propagation (NVP)
|
86 % |
Flame Test Method
|
CMP |
Center Conductor Gauge
|
14 AWG |
Supported Application
|
Video |
Diameter Over Dielectric
|
7.061 mm | 0.278 in |
Diameter Over Jacket, nominal
|
9.042 mm | 0.356 in |
Jacket Thickness
|
0.432 mm | 0.017 in |
Conductor dc Resistance
|
36.089 ohms/km | 11 ohms/kft |
Dielectric Material
|
Foam FEP |
Outer Shield (Braid) Coverage
|
50 % |
Outer Shield (Braid) Material
|
Tinned copper |
Outer Shield (Tape) Material
|
Aluminum/Poly, non-bonded |
Diameter Over Jacket Tolerance
|
±0.008 in |
Diameter Over Outer Shield (Braid)
|
8.204 mm | 0.323 in |
Characteristic Impedance
|
75 ohm |
Characteristic Impedance Tolerance
|
±3 ohm |
Jacket Spark Test Voltage
|
2500 Vac |
Shield dc Resistance
|
5.577 ohms/km | 1.7 ohms/kft |
1.0 MHz
|
0.150 |
10.0 MHz
|
0.450 |
100.0 MHz
|
1.280 |
1000.0 MHz
|
5.040 |
Center Conductor Material
|
Copper-clad steel wire |
50.0 MHz
|
0.900 |
200.0 MHz
|
1.850 |
Inner Shield (Braid) Coverage
|
60 % |
Minimum Bend Radius, loaded, times
|
20 times |
400.0 MHz
|
2.750 |
700.0 MHz
|
3.920 |
900.0 MHz
|
4.720 |
1800.0 MHz
|
7.710 |
Minimum Bend Radius, unloaded, times
|
10 times |
3000.0 MHz
|
9.880 |
Center Conductor Type
|
Solid |
Inner Shield (Braid) Gauge
|
36 AWG |
2200.0 MHz
|
8.500 |
Inner Shield (Braid) Material
|
Tinned copper |
Inner Shield (Tape) Material
|
Aluminum/Poly |
Structural Return Loss
|
15 dB @ 1000–3000 MHz | 20 dB @ 5–1000 MHz |
Outer Shield (Braid) Gauge
|
36 AWG |
Temperature Rating, UL
|
75 °C | 167 °F |
Structural Return Loss Test Method
|
100% Swept Tested |
Diameter Over Center Conductor, specific
|
0.0641 in per 1 strand |
Jacket Thickness, minimum spot
|
0.305 mm | 0.012 in |
Dielectric Strength, conductor to shield
|
4000 Vdc |
1450.0 MHz
|
6.670 |
Diameter Over Inner Shield (Braid)
|
7.595 mm | 0.299 in |
Diameter Over Inner Shield (Tape)
|
7.214 mm | 0.284 in |