В наличии
8106551/DB | O-002-DA-8W-M02NS
Features and Benefits
- Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection
Характеристики
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Product Type
|
Fiber drop cable |
Diameter Over Jacket
|
8 mm | 0.315 in |
Характеристики
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Product Type
|
Fiber drop cable |
Diameter Over Jacket
|
8 mm | 0.315 in |
Jacket Material
|
PE |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Installation temperature
|
-30 °C to +70 °C (-22 °F to +158 °F) |
Storage Temperature
|
-40 °C to +75 °C (-40 °F to +167 °F) |
Cable weight
|
69 kg/km | 46.366 lb/kft |
Jacket Color
|
Black |
Product Series
|
O-DA |
Cable Type
|
Central loose tube |
Environmental Space
|
Aerial, lashed | Buried |
Fiber Type
|
G.652.D and G.657.A1 | G.652.D and G.657.A1 |
Portfolio
|
CommScope® |
Construction Type
|
Armored |
Fibers per Subunit, quantity
|
2 |
Jacket UV Resistance
|
UV stabilized |
Minimum Bend Radius, loaded
|
12 cm | 4.724 in |
Minimum Bend Radius, unloaded
|
8 cm | 3.15 in |
Tensile Load, long term, maximum
|
400 N | 89.924 lbf |
Tensile Load, short term, maximum
|
1334 N | 299.895 lbf |
Jacket Marking
|
Meters |
Total Fiber Count
|
2 |
Fiber Type, quantity
|
2 |
Subunit Type
|
Gel-filled |
Subunit, quantity
|
1 |
Buffer Tube/Subunit Diameter
|
3 mm | 0.118 in |
Compression
|
10 N/mm | 57.101 lb/in |
Compression Test Method
|
FOTP-41 | IEC 60794-1 E3 |
Flex
|
35 cycles |
Flex Test Method
|
FOTP-104 | IEC 60794-1 E6 |
Impact
|
2.94 N-m | 26.021 in lb |
Impact Test Method
|
FOTP-25 | IEC 60794-1 E4 |
Strain
|
See long and short term tensile loads |
Strain Test Method
|
FOTP-33 | IEC 60794-1 E1 |
Twist
|
10 cycles |
Twist Test Method
|
FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum
|
595 m | 1952.1 ft |
Cable Qualification Standards
|
ANSI/ICEA S-110-717 |
Water Penentration
|
24 h |
Water Penentration Test Method
|
FOTP-82 | IEC 60794-1 F5 |
Cable Freeze
|
-2 °C | 28.4 °F |
Cable Freeze Test Method
|
FOTP-98 | IEC 60794-1 F15 |
Drip
|
70 °C | 158 °F |
Drip Test Method
|
FOTP-81 | IEC 60794-1 E14 |
Heat Age Test Method
|
IEC 60794-1 F9 |
Low High Bend
|
-30 °C to +60 °C (-22 °F to +140 °F) |
Low High Bend Test Method
|
FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Temperature Cycle Test Method
|
FOTP-3 | IEC 60794-1 F1 |
Heat Age
|
-40 °C to +85 °C (-40 °F to +185 °F) |
Armor Type
|
Corrugated steel |