В наличии
ANT-SHARING-HUB-6
Features and Benefits
- Supports up to six independent operators
- Works with all CommScope antennas utilizing internal RET systems
- No proprietary RET software required
- Supports up to 24 CommScope RETs when sharing between 2 or more operators
- Band assignments are configurable using PC tool
- Compliant to 3GPP/AISG 2.0
- Multi-RET and Single RET supported, configurable per operator port
Характеристики
Input Voltage
|
10–30 Vdc |
Protocol
|
3GPP/AISG 2.0 compliant |
Ширина
|
261 mm | 10.276 in |
Глубина
|
160 mm | 6.299 in |
Характеристики
Input Voltage
|
10–30 Vdc |
Protocol
|
3GPP/AISG 2.0 compliant |
Ширина
|
261 mm | 10.276 in |
Глубина
|
160 mm | 6.299 in |
Ширина упаковки
|
305 mm | 12.008 in |
Глубина упаковки
|
206 mm | 8.110 in |
Масса, брутто
|
1.7 kg | 3.748 lb |
Цвет
|
Gray |
Масса, нетто
|
1 kg | 2.205 lb |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
CE
|
Compliant with the relevant CE product directives |
Operating Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Material Type
|
ASA |
AISG Input Connector
|
8-pin DIN Male |
AISG Input Connector Quantity
|
6 |
AISG Output Connector
|
8-pin DIN Female |
AISG Output Connector Quantity
|
1 |
Height
|
54.4 mm | 2.142 in |
Electromagnetic Compatibility (EMC)
|
CFR 47 Part 15, Subpart B, Class A | EN 55022 | EN 55032 | EN 61000-4-2 | EN 61000-4-3 | EN 61000-4-4 | EN 61000-4-6 |
Interface Protocol Signal
|
RS-485 |
Lightning Surge Capability
|
5 times @ -8 kA | 5 times @ 8 kA |
Lightning Surge Capability Test Method
|
IEC 61000-4-5 |
Lightning Surge Capability Waveform
|
1.2/50 voltage and 8/20 current combination waveform |
Lightning Surge Test Mode
|
Common mode |
Climatic Sequence Test Method
|
IEC 60068-2-14 |
Cold Exposure Test Method
|
IEC 60068-2-1 |
Corrosion Test Method
|
IEC 60068-2-11, Test Condition Ka | IEC 60068-2-52, Test Condition Kb |
Damp Heat Exposure Test Method
|
IEC 60068-2-30, Test Condition Db |
Heat Exposure Test Method
|
IEC 60068-2-2 |
Ingress Protection Test Method
|
IEC 60529:2001, IP56 |
Packaged Product Shock Test Method
|
ASTM D4169 | GR-63-CORE, Section 4.1.1 |
Rain Simulation Test Method
|
IEC 60068-2-18, Test Condition Ra, Method 1 |
UV Resistance Test Method
|
IEC 60068-2-5, Test Condition B |
Vibration Test Method
|
ASTM D4169 | IEC 60068-2-6 |
Electrical Specifications Footnote
|
If using a single operator, the load capability is dependent on controller power supply, cable wire gauge, and other factors. Please contact CommScope for any questions |
Height, packed
|
128 mm | 5.039 in |