В наличии
CSPM7G0
Features and Benefits
- Engineered to deliver maximum RF performance within the operating frequency band
- The raised body allows moisture to drain behind the unit and uses a priority plating for use in harsh environments
- Includes zinc die cast body with a soldered back plate for superior RF shielding
- The machined “F” ports -with an innovative four-sided contact- provide excellent retention and electrical performance
Характеристики
Impedance
|
75 ohm |
Operating Frequency Band
|
5 – 1675 MHz |
Ширина упаковки
|
235 mm | 9.252 in |
Длина упаковки
|
340 mm | 13.386 in |
Характеристики
Impedance
|
75 ohm |
Operating Frequency Band
|
5 – 1675 MHz |
Ширина упаковки
|
235 mm | 9.252 in |
Длина упаковки
|
340 mm | 13.386 in |
Масса, брутто
|
17.69 kg | 39 lb |
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Product Type
|
Passive gateway |
Application
|
Indoor | Outdoor |
Height, packed
|
220 mm | 8.661 in |
Mounting
|
Horizontal or All Port Down |
Product Brand
|
HomeConnect® |
Device Type
|
Passive gateway |
Carton Quantity
|
50 |
Return Loss at Frequency Band, input, minimum
|
18 dB @ 5–1218 MHz |
Surge Capability Test Method
|
IEEE C62.41-1991-B3 (500 V to 6 kV, 3000 A Combination wave) on Input Port | IEEE C62.41-1991-B3 (500 V to 6 kV, 500 A Ring wave) on all Output Ports |
Shielding Effectiveness, minimum
|
100 dB |
Frequency Response
|
±0.4 dB @ 5–1218 MHz |
Power Passing
|
No |
Grounding and Bonding Standard
|
UL 467 Ground Clamp Communication |
Output Port
|
1 High Output Access (CATV + MoCA) | 1 Low Output Access (CATV + MoCA) | 4 Home (MoCA) |
Insertion Loss at Frequency Band, input to any Home output port
|
≥ 40dB @ 5–1002 MHz |
Insertion Loss at Frequency Band, input to high output Access port
|
≤ 4.0 dB @ 5–400 MHz | ≤ 5.0 dB @ 400–600 MHz | ≤ 5.5 dB @ 600–1218 MHz |
Insertion Loss at Frequency Band, input to low output Access port
|
≤ 7.7 dB @ 5–400 MHz | ≤ 8.5 dB @ 400–600 MHz | ≤ 9.0 dB @ 600–1218 MHz |
Return Loss at Frequency Band, Access output port
|
≥ 18 dB @ 5–1218 MHz | ≥ 5 dB @ 1275–1675 MHz |
Return Loss at Frequency Band, Home output port
|
≥ 5 dB @ 1275–1675 MHz |
Operating Frequency Band Access Port
|
CATV 5–1218 MHz | MoCA 1275–1675 MHz |
Operating Frequency Band Home Port
|
MoCA 1125–1675 MHz |
Isolation at Frequency Band, access to access output
|
≤30 dB @ 1275–1675 MHz | ≥25 dB @ 5–10 MHz | ≥25 dB @ 86–1218 MHz | ≥35 dB @ 11–85 MHz |
Isolation at Frequency Band, access to home output, minimum
|
28 dB @ 1125–1675 MHz |
Isolation at Frequency Band, home to home output, minimum
|
16 dB @ 1125–1675 MHz |