В наличии
CSM3G
Features and Benefits
- Engineered to deliver maximum RF performance within the operating frequency band
- The raised body allows moisture to drain behind the unit and uses a priority plating for use in harsh environments
- Includes zinc die cast body with a soldered back plate for superior RF shielding
- The machined “F” ports -with an innovative four-sided contact- provide excellent retention and electrical performance
Характеристики
Impedance
|
75 ohm |
Operating Frequency Band
|
5 – 1675 MHz |
Ширина упаковки
|
360 mm | 14.173 in |
Длина упаковки
|
525 mm | 20.669 in |
Характеристики
Impedance
|
75 ohm |
Operating Frequency Band
|
5 – 1675 MHz |
Ширина упаковки
|
360 mm | 14.173 in |
Длина упаковки
|
525 mm | 20.669 in |
Масса, брутто
|
25 kg | 55.115 lb |
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
CE
|
Compliant with the relevant CE product directives |
Operating Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Product Type
|
Coaxial splitter |
Application
|
Indoor | Outdoor |
Height, packed
|
195 mm | 7.677 in |
Mounting
|
Horizontal |
Product Brand
|
HomeConnect® |
Device Type
|
Splitter |
Safety Standard
|
SCTE | UL 467 |
Carton Quantity
|
300 |
Return Loss at Frequency Band, input, minimum
|
5 dB @ 1218–1675 MHz | 15 dB @ 1002–1218 MHz | 18 dB @ 5-1002 MHz |
Return Loss at Frequency Band, output, minimum
|
5 dB @ 1218-1675 MHz | 15 dB @ 1002–1218 MHz | 18 dB @ 5–1002 MHz |
Surge Capability Test Method
|
IEEE C62.41-1991-B3 (500 V to 6 kV, 500 A Ring wave) on all Output Ports | IEEE C62.41.1991-B3 (6 kV, 3000 A, Combination wave) on input port |
Video Ports, quantity
|
3 |
Shielding Effectiveness, minimum
|
120 dB |
Isolation at Frequency Band, output to output, minimum
|
25.0 dB @ 5-10 MHz | 20 dB @ 1002-1218 MHz | 25 dB @ 85-1002 MHz | 35 dB @ 10-85 MHz |
Frequency Response
|
±0.4 dB @ 5–1218 MHz | ±1.4 dB @ 1218–1675 MHz |
Power Passing
|
No |
Grounding and Bonding Standard
|
UL 467 Ground Clamp Communication |
Isolation at Frequency Band, output to output, maximum
|
30 dB @ 1275–1675 MHz |
Insertion Loss at Frequency Band, port 1, maximum
|
3.7 dB @ 5–400 MHz | 4.0 dB @ 400–1218 MHz | 6.7 dB @ 1218–1675 MHz |
Insertion Loss at Frequency Band, port 2, maximum
|
11.5 dB @ 1218–1675 MHz | 7.5 dB @ 400–1218 MHz | 7.5 dB @ 5–400 MHz |