В наличии
S-LN
Features and Benefits
- CommScope’s outside plant fiber cables are made with high-performance, standards-compliant materials
- The portfolio includes both armored and dielectric designs available with dry or gel-filled tubes
- Superior mechanical and optical performance with unmatched stability and quality
Характеристики
Operating Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Product Type
|
Fiber OSP cable |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Installation temperature
|
-30 °C to +70 °C (-22 °F to +158 °F) |
Характеристики
Operating Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Product Type
|
Fiber OSP cable |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Installation temperature
|
-30 °C to +70 °C (-22 °F to +158 °F) |
Jacket Color
|
Black |
Product Series
|
S-LN |
Cable Type
|
Stranded loose tube |
Environmental Space
|
Aerial, self-support |
Portfolio
|
CommScope® |
Construction Type
|
Non-armored |
Jacket UV Resistance
|
UV stabilized |
Jacket Marking
|
Feet | Meters |
Subunit Type
|
Gel-filled |
Compression
|
22 N/mm | 125.623 lb/in |
Compression Test Method
|
FOTP-41 | IEC 60794-1 E3 |
Flex
|
35 cycles |
Flex Test Method
|
FOTP-104 | IEC 60794-1 E6 |
Impact
|
2.94 N-m | 26.021 in lb |
Impact Test Method
|
FOTP-25 | IEC 60794-1 E4 |
Strain
|
See long and short term tensile loads |
Strain Test Method
|
FOTP-33 | IEC 60794-1 E1 |
Twist
|
10 cycles |
Twist Test Method
|
FOTP-85 | IEC 60794-1 E7 |
Heat Age Test Method
|
IEC 60794-1 F9 |
Low High Bend
|
-30 °C to +60 °C (-22 °F to +140 °F) |
Low High Bend Test Method
|
FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Temperature Cycle Test Method
|
FOTP-3 | IEC 60794-1 F1 |
Heat Age
|
-40 °C to +85 °C (-40 °F to +185 °F) |
Поддержка продукта