В наличии
860646630/DB | O-096-LN-8G-M12NS/20G/BK
Характеристики
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Product Type
|
Fiber OSP cable |
Diameter Over Jacket
|
10.5 mm | 0.413 in |
Характеристики
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Product Type
|
Fiber OSP cable |
Diameter Over Jacket
|
10.5 mm | 0.413 in |
Jacket Material
|
PE |
Regional Availability
|
EMEA |
Installation temperature
|
-30 °C to +70 °C (-22 °F to +158 °F) |
Storage Temperature
|
-40 °C to +75 °C (-40 °F to +167 °F) |
Cable weight
|
86 kg/km | 57.789 lb/kft |
Jacket Color
|
Black |
Product Series
|
O-LN |
Cable Type
|
Stranded loose tube |
Environmental Space
|
Aerial, lashed | Buried |
Fiber Type
|
G.657.A2 | G.657.A2 |
Portfolio
|
CommScope® |
Construction Type
|
Non-armored |
Fibers per Subunit, quantity
|
12 |
Jacket UV Resistance
|
UV stabilized |
Minimum Bend Radius, loaded
|
158 mm | 6.220 in |
Minimum Bend Radius, unloaded
|
105 mm | 4.134 in |
Tensile Load, long term, maximum
|
800 N | 179.847 lbf |
Tensile Load, short term, maximum
|
2700 N | 606.984 lbf |
Jacket Marking
|
Meters |
Total Fiber Count
|
96 |
Fiber Type, quantity
|
96 |
Subunit Type
|
Gel-filled |
Subunit, quantity
|
8 |
Buffer Tube/Subunit Diameter
|
2 mm | 0.079 in |
Compression
|
22 N/mm | 125.623 lb/in |
Compression Test Method
|
IEC 60794-1 E3 |
Flex
|
35 cycles |
Flex Test Method
|
IEC 60794-1 E6 |
Impact
|
2.94 N-m | 26.021 in lb |
Impact Test Method
|
IEC 60794-1 E4 |
Strain
|
See long and short term tensile loads |
Strain Test Method
|
IEC 60794-1 E1 |
Twist
|
10 cycles |
Twist Test Method
|
IEC 60794-1 E7 |
Vertical Rise, maximum
|
946 m | 3103.675 ft |
Cable Qualification Standards
|
ANSI/ICEA S-87-640 | EN 187105 | IEC 60794-1-2 |
Water Penentration
|
24 h |
Water Penentration Test Method
|
IEC 60794-1 F5 |
Cable Freeze
|
-2 °C | 28.4 °F |
Cable Freeze Test Method
|
IEC 60794-1 F15 |
Drip
|
70 °C | 158 °F |
Drip Test Method
|
IEC 60794-1 E14 |
Heat Age Test Method
|
IEC 60794-1 F9 |
Low High Bend
|
-30 °C to +60 °C (-22 °F to +140 °F) |
Low High Bend Test Method
|
IEC 60794-1 E11 |
Temperature Cycle
|
-40 °C to +70 °C (-40 °F to +158 °F) |
Temperature Cycle Test Method
|
IEC 60794-1 F1 |
Heat Age
|
-40 °C to +85 °C (-40 °F to +185 °F) |
Поддержка продукта