В наличии
CNT-400-FR
Характеристики
Operating Frequency Band
|
30 – 6000 MHz |
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
Характеристики
Operating Frequency Band
|
30 – 6000 MHz |
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Product Type
|
Braided coaxial cable |
Diameter Over Jacket
|
10.29 mm | 0.405 in |
Braid Coverage
|
90 % |
Jacket Material
|
Non-halogenated, fire retardant polyolefin |
Product Brand
|
CNT® |
Packaging Type
|
Reel |
Installation temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Storage Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Cable weight
|
0.07 kg/m | 0.047 lb/ft |
Jacket Color
|
Black |
Fire Retardancy Test Method
|
UL VW1/CATVX |
Toxicity Index Test Method
|
IEC 60754-2 |
Peak Power
|
16 kW |
Product Series
|
CNT-400 |
Cable Type
|
CNT-400 |
Capacitance
|
78 pF/m | 23.774 pF/ft |
EN50575 CPR Cable EuroClass Fire Performance
|
Dca |
CENELEC
|
EN 50575 compliant, Declaration of Performance (DoP) available |
dc Test Voltage
|
2500 V |
Cable Impedance
|
50 ohm |
EN50575 CPR Cable EuroClass Smoke Rating
|
s2 |
EN50575 CPR Cable EuroClass Droplets Rating
|
d2 |
Nominal Size
|
0.400 in |
Minimum Bend Radius, Single Bend
|
25.4 mm | 1 in |
Diameter Over Dielectric
|
7.24 mm | 0.285 in |
Dielectric Material
|
Foam PE |
Velocity
|
85 % |
Shield Tape Material
|
Aluminum |
50.0 MHz
|
3.180 |
900.0 MHz
|
12.800 |
1800.0 MHz
|
18.400 |
2000.0 MHz
|
19.400 |
2500.0 MHz
|
22.000 |
2400.0 MHz
|
21.650 |
3000.0 MHz
|
24.600 |
450.0 MHz
|
8.860 |
1500.0 MHz
|
16.700 |
Inner Conductor OD
|
2.74 mm | 0.108 in |
Outer Conductor OD
|
8.08 mm | 0.318 in |
dc Resistance, Inner Conductor
|
4.49 ohms/km | 1.369 ohms/kft |
dc Resistance, Outer Conductor
|
5.61 ohms/km | 1.71 ohms/kft |
Jacket Spark Test Voltage (rms)
|
4000 V |
30.0 MHz
|
2.490 |
150.0 MHz
|
4.920 |
4000.0 MHz
|
28.870 |
4500.0 MHz
|
30.840 |
5000.0 MHz
|
32.810 |
6000.0 MHz
|
36.420 |
Inner Conductor Material
|
Copper-clad aluminum wire |
Tensile Strength
|
73 kg | 160.937 lb |
Bending Moment
|
0.7 N-m | 6.196 in lb |
Flat Plate Crush Strength
|
0.7 kg/mm | 39.198 lb/in |
Maximum Frequency
|
16.2 GHz |
Shielding Effectiveness
|
90 dB |
220.0 MHz
|
6.230 |
5200.0 MHz
|
33.460 |
5500.0 MHz
|
34.780 |
5800.0 MHz
|
35.760 |
Braid Material
|
Tinned copper |
Smoke Index Test Method
|
IEC 61034 |
Diameter Over Tape
|
7.391 mm | 0.291 in |