В наличии
CNT-300A-FR
Характеристики
Operating Frequency Band
|
30 – 6000 MHz |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Product Type
|
Braided coaxial cable |
Характеристики
Operating Frequency Band
|
30 – 6000 MHz |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Product Type
|
Braided coaxial cable |
Diameter Over Jacket
|
7.62 mm | 0.3 in |
Braid Coverage
|
87 % |
Jacket Material
|
Non-halogenated, fire retardant polyolefin |
Product Brand
|
CNT® |
Packaging Type
|
Reel |
Installation temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Storage Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Cable weight
|
0.07 kg/m | 0.047 lb/ft |
Jacket Color
|
Black |
Toxicity Index Test Method
|
IEC 60754-2 |
Peak Power
|
10 kW |
Product Series
|
CNT-300 |
Cable Type
|
CNT-300 |
Capacitance
|
80.4 pF/m | 24.506 pF/ft |
EN50575 CPR Cable EuroClass Fire Performance
|
Dca |
CENELEC
|
EN 50575 compliant, Declaration of Performance (DoP) available |
dc Test Voltage
|
2500 V |
Cable Impedance
|
50 ohm |
EN50575 CPR Cable EuroClass Smoke Rating
|
s2 |
EN50575 CPR Cable EuroClass Droplets Rating
|
d2 |
Nominal Size
|
0.300 in |
Minimum Bend Radius, Single Bend
|
22.352 mm | 0.88 in |
Diameter Over Dielectric
|
4.83 mm | 0.19 in |
Dielectric Material
|
Foam PE |
Velocity
|
83 % |
Shield Tape Material
|
Aluminum |
50.0 MHz
|
4.900 |
900.0 MHz
|
19.400 |
1800.0 MHz
|
28.200 |
2000.0 MHz
|
29.800 |
2500.0 MHz
|
33.800 |
3000.0 MHz
|
37.400 |
450.0 MHz
|
13.100 |
1500.0 MHz
|
25.300 |
Inner Conductor OD
|
1.78 mm | 0.07 in |
Outer Conductor OD
|
5.66 mm | 0.223 in |
dc Resistance, Inner Conductor
|
11.05 ohms/km | 3.368 ohms/kft |
dc Resistance, Outer Conductor
|
8.5 ohms/km | 2.591 ohms/kft |
Jacket Spark Test Voltage (rms)
|
3500 V |
30.0 MHz
|
3.800 |
150.0 MHz
|
7.900 |
4000.0 MHz
|
44.610 |
4500.0 MHz
|
47.750 |
5000.0 MHz
|
50.520 |
6000.0 MHz
|
55.800 |
Inner Conductor Material
|
Copper-clad aluminum wire |
Tensile Strength
|
23 kg | 50.706 lb |
Bending Moment
|
0.5 N-m | 4.425 in lb |
Flat Plate Crush Strength
|
0.5 kg/mm | 27.999 lb/in |
Maximum Frequency
|
24.5 GHz |
Shielding Effectiveness
|
90 dB |
220.0 MHz
|
9.500 |
5200.0 MHz
|
51.830 |
5500.0 MHz
|
53.140 |
5800.0 MHz
|
54.780 |
Braid Material
|
Tinned copper |
Smoke Index Test Method
|
IEC 61034 |
Diameter Over Tape
|
5.003 mm | 0.197 in |
3500.0 MHz
|
41.500 |