В наличии
RCT7-CPUS-4A-RNA
Характеристики
Operating Frequency Band
|
50 – 2400 MHz |
Polarization
|
Vertical |
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
Характеристики
Operating Frequency Band
|
50 – 2400 MHz |
Polarization
|
Vertical |
ROHS
|
Compliant |
CHINA-ROHS
|
Below maximum concentration value |
REACH-SVHC
|
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-30 °C to +80 °C (-22 °F to +176 °F) |
Product Type
|
Radiating cable |
Jacket Material
|
Non-halogenated, fire retardant polyolefin |
Product Brand
|
RADIAX® |
Attenuation Tolerance
|
±5% |
Installation temperature
|
-30 °C to +60 °C (-22 °F to +140 °F) |
Storage Temperature
|
-30 °C to +80 °C (-22 °F to +176 °F) |
Attenuation, Ambient Temperature
|
20 °C | 68 °F |
Average Power, Ambient Temperature
|
40 °C | 104 °F |
Cable weight
|
0.83 kg/m | 0.558 lb/ft |
Jacket Color
|
Black |
Fire Retardancy Test Method
|
IEC 60332-1-2 | IEC 60332-3C-24 |
Toxicity Index Test Method
|
IEC 60754-1 | IEC 60754-2 |
Peak Power
|
302 kW |
Product Series
|
RCT7 |
Cable Type
|
Radiating Mode (RCT) Series |
dc Test Voltage
|
15000 V |
Cable Impedance
|
50 ohm ±2 ohm |
Average Power, Inner Conductor Temperature
|
100 °C | 212 °F |
Nominal Size
|
1-5/8 in |
Minimum Bend Radius, Single Bend
|
508 mm | 20 in |
Dielectric Material
|
Foam PE |
Velocity
|
93 % |
100.0 MHz
|
0.600 |
700.0 MHz
|
1.600 |
900.0 MHz
|
2.200 |
1800.0 MHz
|
5.200 |
2000.0 MHz
|
4.800 |
2300.0 MHz
|
4.700 |
1900.0 MHz
|
4.800 |
2400.0 MHz
|
4.600 |
350.0 MHz
|
1.100 |
450.0 MHz
|
1.300 |
1700.0 MHz
|
6.000 |
2200.0 MHz
|
4.600 |
Outer Conductor Material
|
Copper foil |
Diameter Over Jacket, maximum
|
49.784 mm | 1.96 in |
Inner Conductor OD
|
18.161 mm | 0.715 in |
Outer Conductor OD
|
43.815 mm | 1.725 in |
dc Resistance, Inner Conductor
|
1.435 ohms/km | 0.437 ohms/kft |
dc Resistance, Outer Conductor
|
1.969 ohms/km | 0.6 ohms/kft |
Insulation Resistance
|
100000 MOhms-km |
Jacket Spark Test Voltage (rms)
|
10000 V |
150.0 MHz
|
0.700 |
800.0 MHz
|
1.900 |
2100.0 MHz
|
4.600 |
Inner Conductor Material
|
Corrugated copper tube |
Tensile Strength
|
215 kg | 473.993 lb |
Bending Moment
|
16 N-m | 141.612 in lb |
Flat Plate Crush Strength
|
0.8 kg/mm | 44.798 lb/in |
Smoke Index Test Method
|
IEC 61034 |
Recommended Distance from the Wall
|
101.6 mm | 4 in |
Recommended Hanger Spacing
|
1.3 m | 4.265 ft |
Attenuation Test Method
|
IEC 61196-4 |
VSWR Installed, typical, 1700–2700 MHz
|
1.3799999952316284 |
VSWR Installed, typical, 50–960 MHz
|
1.2999999523162842 |
VSWR on Reel, typical
|
1.4299999475479126 |
75.0 MHz
|
0.500 |
Coupling Loss Test Method
|
IEC 61196-4 |
Coupling Loss Tolerance
|
±5 dB |
Indication of Slot Alignment
|
Yes–bumps face the wall |
Optimum Operating Frequency Band
|
800 – 960 MHz | 1700 – 2400 MHz |
Stop Bands
|
1110 – 1650 MHz |