В наличии
770022003 | F677TSVR XP CAT6
Характеристики
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +75 °C (-40 °F to +167 °F) |
Product Type
|
Hybrid cable, coax and twisted pair |
Diameter Over Jacket
|
7.061 mm | 0.278 in |
Характеристики
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +75 °C (-40 °F to +167 °F) |
Product Type
|
Hybrid cable, coax and twisted pair |
Diameter Over Jacket
|
7.061 mm | 0.278 in |
Jacket Material
|
PVC |
Regional Availability
|
Asia | Australia/New Zealand | EMEA | Latin America | North America |
Packaging Type
|
Reel |
Conductor Material
|
Bare copper |
Installation temperature
|
-18 °C to +60 °C (0.4 °F to +140 °F) |
Cable weight
|
89.290 kg/km | 60 lb/kft |
Jacket Color
|
Black |
Cable Type
|
Hybrid |
Environmental Space
|
Non-plenum |
Portfolio
|
CommScope® |
ANSI/TIA Category
|
6 |
Safety Standard
|
ETL | cETL |
Capacitance
|
52.493 pF/m | 16 pF/ft |
Cable Length
|
304.8 m | 1000 ft |
Construction Type
|
Non-armored |
Nominal Velocity of Propagation (NVP)
|
82 % |
Flame Test Method
|
CMR |
Center Conductor Gauge
|
18 AWG |
Diameter Over Conductor, singles, specific
|
0.0254 in per 1 strand |
Diameter Over Dielectric
|
4.572 mm | 0.18 in |
Jacket Thickness
|
0.762 mm | 0.03 in |
Conductor dc Resistance
|
21.325 ohms/km | 6.5 ohms/kft |
Dielectric Material
|
Foam PE |
Outer Shield (Tape) Material
|
Aluminum/Poly, non-bonded |
Diameter Over Center Conductor Tolerance
|
±0.0004 in |
Diameter Over Dielectric Tolerance
|
±0.004 in |
Diameter Over Jacket Tolerance
|
±0.008 in |
Diameter Over Outer Shield (Braid)
|
5.385 mm | 0.212 in |
Characteristic Impedance
|
75 ohm |
Characteristic Impedance Tolerance
|
±3 ohm |
Jacket Spark Test Voltage
|
2500 Vac |
Shield dc Resistance
|
16.076 ohms/km | 4.9 ohms/kft |
1.0 MHz
|
1.210 |
10.0 MHz
|
2.160 |
100.0 MHz
|
6.300 |
1000.0 MHz
|
20.040 |
Center Conductor Material
|
Copper-clad steel wire |
50.0 MHz
|
4.620 |
200.0 MHz
|
8.660 |
Inner Shield (Braid) Coverage
|
77 % |
Minimum Bend Radius, loaded, times
|
20 times |
400.0 MHz
|
12.230 |
700.0 MHz
|
16.560 |
900.0 MHz
|
18.990 |
1200.0 MHz
|
22.070 |
1800.0 MHz
|
27.650 |
Minimum Bend Radius, unloaded, times
|
10 times |
2500.0 MHz
|
32.700 |
3000.0 MHz
|
35.820 |
Center Conductor Type
|
Solid |
Inner Shield (Braid) Gauge
|
34 AWG |
2200.0 MHz
|
30.670 |
Inner Shield (Braid) Material
|
Aluminum |
Inner Shield (Tape) Material
|
Aluminum/Poly, bonded |
Structural Return Loss
|
15 dB @ 5–2200 MHz |
Temperature Rating, UL
|
60 °C | 140 °F |
Structural Return Loss Test Method
|
100% Swept Tested |
Diameter Over Center Conductor, specific
|
0.0403 in per 1 strand |
Jacket Thickness, minimum spot
|
0.457 mm | 0.018 in |
Dielectric Strength, conductor to shield
|
2500 Vdc |
1450.0 MHz
|
24.570 |
Overall Cable Width
|
14.3 mm | 0.563 in |
Diameter Over Conductor
|
0.023 in per 1 strand |