В наличии
PTS1-HRL
Характеристики
Performance Note
|
Attenuation values typical, guaranteed within 5% |
Operating Frequency Band
|
100 – 12000 MHz |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +150 °C (-40 °F to +302 °F) |
Характеристики
Performance Note
|
Attenuation values typical, guaranteed within 5% |
Operating Frequency Band
|
100 – 12000 MHz |
ISO 9001:2015
|
Designed, manufactured and/or distributed under this quality management system |
Operating Temperature
|
-40 °C to +150 °C (-40 °F to +302 °F) |
Product Type
|
Coaxial wireless cable |
Diameter Over Jacket
|
7.366 mm | 0.29 in |
Jacket Material
|
TPC-ET |
3rd Order IMD
|
-107 dBm |
Product Brand
|
HELIAX® |
Installation temperature
|
-40 °C to +60 °C (-40 °F to +140 °F) |
Storage Temperature
|
-40 °C to +85 °C (-40 °F to +185 °F) |
Attenuation, Ambient Temperature
|
20 °C | 68 °F |
Average Power, Ambient Temperature
|
40 °C | 104 °F |
Cable weight
|
0.1 kg/m | 0.067 lb/ft |
Jacket Color
|
Brown |
Peak Power
|
6.4 kW |
Product Series
|
PTS1-50-P |
Capacitance
|
80.7 pF/m | 24.597 pF/ft |
2200–2700 MHz
|
1.135 |
dc Test Voltage
|
1600 V |
Cable Impedance
|
50 ohm ±2 ohm |
Average Power, Inner Conductor Temperature
|
200 °C | 392 °F |
Nominal Size
|
1/4 in |
1700–2200 MHz
|
1.135 |
Minimum Bend Radius, multiple Bends
|
25.4 mm | 1 in |
Minimum Bend Radius, Single Bend
|
25.4 mm | 1 in |
680–960 MHz
|
1.135 |
Diameter Over Dielectric
|
4.826 mm | 0.19 in |
Dielectric Material
|
Foam FEP |
Velocity
|
82 % |
1.0 MHz
|
0.368 |
10.0 MHz
|
1.914 |
100.0 MHz
|
6.189 |
1000.0 MHz
|
21.423 |
50.0 MHz
|
4.325 |
108.0 MHz
|
6.443 |
200.0 MHz
|
8.894 |
400.0 MHz
|
12.891 |
700.0 MHz
|
17.547 |
1800.0 MHz
|
29.885 |
2000.0 MHz
|
31.730 |
2300.0 MHz
|
34.399 |
2500.0 MHz
|
36.067 |
500.0 MHz
|
14.566 |
2700.0 MHz
|
37.899 |
3000.0 MHz
|
40.102 |
300.0 MHz
|
11.118 |
450.0 MHz
|
13.735 |
600.0 MHz
|
16.097 |
1500.0 MHz
|
26.887 |
1700.0 MHz
|
28.925 |
2200.0 MHz
|
33.529 |
1250.0 MHz
|
24.265 |
Outer Conductor Material
|
Corrugated copper |
Flexibility
|
Superflexible |
Inner Conductor OD
|
1.8796 mm | 0.074 in |
Outer Conductor OD
|
6.35 mm | 0.25 in |
dc Resistance, Inner Conductor
|
6.234 ohms/km | 1.9 ohms/kft |
dc Resistance, Outer Conductor
|
6.562 ohms/km | 2 ohms/kft |
Inductance
|
0.207 µH/m | 0.063 µH/ft |
Insulation Resistance
|
100000 MOhms-km |
Jacket Spark Test Voltage (rms)
|
4000 V |
2.0 MHz
|
0.719 |
20.0 MHz
|
2.719 |
30.0 MHz
|
3.320 |
150.0 MHz
|
7.636 |
174.0 MHz
|
8.315 |
512.0 MHz
|
14.757 |
800.0 MHz
|
18.866 |
824.0 MHz
|
19.176 |
894.0 MHz
|
20.029 |
960.0 MHz
|
20.860 |
2100.0 MHz
|
32.621 |
3400.0 MHz
|
43.152 |
4000.0 MHz
|
47.429 |
5000.0 MHz
|
54.405 |
6000.0 MHz
|
60.464 |
Inner Conductor Material
|
Silver-plated copper wire |
Number of Bends, minimum
|
15 |
Tensile Strength
|
68 kg | 149.914 lb |
Bending Moment
|
0.8 N-m | 7.081 in lb |
Flat Plate Crush Strength
|
1.8 kg/mm | 100.795 lb/in |
Number of Bends, typical
|
20 |
8000.0 MHz
|
72.435 |
8800.0 MHz
|
76.701 |
10000.0 MHz
|
82.620 |
12000.0 MHz
|
92.938 |
0.5 MHz
|
0.265 |